Output: 12VDC or 24VDC selectable output. Burglar Alarm Applications(UL 603): 12VDC = 11.5VDC-13VDC. 24VDC = 23VDC-26VDC. 12VDC @ 4 amp or 24VDC @ 3 amp supply current. Class 2 Rated power limited output. Filtered and electronically regulated output. Short circuit and thermal overload protection.
Battery Backup: Built-in charger for sealed lead acid or gel type batteries. Automatic switch over to stand-by battery when AC fails. Maximum charge current 0.7 amp.
Supervision: AC fail supervision (form C contacts). Low battery supervision (form C contacts). Battery presence supervision (form C contacts).
Visual Indicators: AC input, DC output and Battery LED indicators.
Electrical: Operating temperature: 0° C to 49° C ambient. BTU/Hr. : 12VDC: 14.71 - 16.63BTU/Hr. 24VDC: 29.43 - 32.41BTU/Hr. System AC input VA requirement: 402.5VA.